Siemens G130 List Manual page 61

Hide thumbs Also See for G130:
Table of Contents

Advertisement

r0050.0...3
CO/BO: Command Data Set CDS effective / CDS effective
VECTOR_G, B_INF
Can be changed: -
Data type: Unsigned8
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Displays the effective Command Data Set (CDS).
Bit field:
Bit
00
01
02
03
Dependency:
Refer to: p0810, p0811, r0836
Note:
The Command Data Set selected using a binector input (e.g. p0810) is displayed using r0836.
r0051.0...4
CO/BO: Drive Data Set DDS effective / DDS effective
VECTOR_G, ENC
Can be changed: -
Data type: Unsigned8
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Displays the effective Drive Data Set (DDS).
Bit field:
Bit
00
01
02
03
04
Dependency:
Refer to: p0820, p0821, p0822, p0823, p0824, r0837
Note:
The drive data set changeover is suppressed when selecting the motor identification, during the rotating
measurement, the encoder calibration and the friction characteristic record.
r0056.0...15
CO/BO: Status word, closed-loop control / ZSW cl-loop ctrl
VECTOR_G
Can be changed: -
Data type: Unsigned16
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Display and BICO output for the status word of the closed-loop control.
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Signal name
CDS eff bit 0
CDS eff bit 1
CDS eff bit 2
CDS eff bit 3
Signal name
DDS eff bit 0
DDS eff bit 1
DDS eff bit 2
DDS eff bit 3
DDS eff bit 4
Signal name
Initialization completed
De-magnetizing completed
Pulse enable available
Soft starting present
Magnetizing completed
Voltage boost when starting
Acceleration voltage
Frequency negative
Field weakening active
Voltage limit active
Slip limit active
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
ON
ON
ON
ON
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
ON
ON
ON
ON
ON
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Active
Active
Yes
Yes
Yes
Yes
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 8560
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
OFF
OFF
OFF
OFF
Access level: 2
Func. diagram: 8565
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
OFF
OFF
OFF
OFF
OFF
Access level: 3
Func. diagram: 2526
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
No
Inactive
Inactive
No
No
No
No
FP
-
-
-
-
FP
-
-
-
-
-
FP
-
-
-
-
-
6301
6301
6719
-
6714
6310
61

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents