r0103
Application-specific view / Appl_spec view
VECTOR_G, B_INF
Can be changed: -
Data type: Unsigned16
P-Group: Closed-loop control
Not for motor type: -
Min
0
Description:
Displays the application-specific view of the individual drive object.
Dependency:
Refer to: p0107, r0107
p0105
Activate/deactivate drive object / DO act/deact
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: Integer16
CU_G130_DP,
P-Group: Closed-loop control
CU_G150_DP
Not for motor type: -
Min
0
Description:
Setting to activate/deactivate a drive object.
Value:
0:
1:
Dependency:
Refer to: r0106
Notice:
The following applies when activating:
If components are inserted for the first time and the appropriate drive object is activated, then the drive system is
automatically booted. To do this, the pulses of all of the drive objects must be suppressed.
p0105
Activate/deactivate drive object / DO act/deact
VECTOR_G, B_INF,
Can be changed: T
TM120, TM150, TB30,
Data type: Integer16
ENC, HUB
P-Group: Closed-loop control
Not for motor type: -
Min
0
Description:
Setting to activate/deactivate a drive object.
Value:
0:
1:
2:
Recommendation:
After inserting all of the components of a drive object, before activating, first wait for Alarm A01316.
Dependency:
When activating drive objects with the safety functions enabled, the following applies:
After reactivating, a warm restart (p0009 = 30, p0976 = 2, 3) or POWER ON should be carried out.
Refer to: r0106
Refer to: A01314
Notice:
The following applies when activating:
If components are inserted for the first time and the appropriate drive object is activated, then the drive system is
automatically booted. To do this, the pulses of all of the drive objects must be suppressed.
Note:
For value = 0, 2:
When a drive object is deactivated it no longer outputs any errors.
If value = 0:
All components of the drive object were completely commissioned and are deactivated using this value. They can be
removed from the DRIVE-CLiQ without any error.
If a component has been deactivated, only the component with the correct serial number may be inserted, or none at
all.
If value = 1:
All components of the drive object must be available for error-free operation.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Deactivate drive object
Activate drive object
Deactivate drive object
Activate drive object
Drive object deactivate and not present
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
65535
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1