Maintenance Commands
Table 7-16
lists the event type, the text that appears in the Event Description
field, a further explanation of the condition, and the type of data in the Event 1
and Event 2 fields.
Table 7-16. Denied IP events
Event
Type
Event Description
1907
IP RRJ-Invalid RAS
addr
1908
IP RRJ-Invld call
SigAddr
1909
IP RRJ-RemoteOfc
misadmin
1910
IP RRJ-H323
UserObj undef
1911
IP RRJ-Exceed max
endpts
1912
IP RRJ-Exceed
ProdID/Ver
7-120
Issue 1 May 2002
Explanation
Registration Rejected because the
RAS address in the RRQ is
invalid.
IP Registration Rejection because
signaling address in the RRQ is
invalid.
Registration rejected because:
1. Remote Office is enabled on
the Signaling Group screen,
but the RRQ is not from a
supported Remote Office
product.
2. The RRQ is from a supported
Remote Office product, but
Remote Office not enabled on
the Signaling Group screen.
3. Remote Office is enabled on
the Signaling Group screen,
but the Terminal Type in the
RRQ is not valid.
Registration rejected because
there is no H323 User Object.
Registration rejected because the
capacity for either registered
endpoints or Remote Office
endpoints is exceeded. Check
maximum allowed in the system
on page 1 of the System
Parameters Customer Options
screen.
Registration rejected because the
maximum number of registered
endpoints of a specific product ID
and version is exceeded. Check
the limit on the System
Parameters Customer Options
screen.
Event
Event
Data 1
Data 2
0
IP address
that sent the
RRQ
0
IP address
0
IP address
0
IP address
0
1st part: #
of RO
stations;
2nd part: #
of IP
stations,
respectively
T/S: IP
1st part:
Product
registered
from the
limit; 2nd
System
part: actual
Parameters
count,
Customer
respectively
Options
screen