Maintenance Commands

list measurements ds1

list measurements ds1 UUCSS [print | schedule]
list measurements ds1-log UUCSS [print | schedule]
list measurements ds1-facility UUCSSf [log | summary] [print | schedule]
The list measurements ds1 and l ist measurements ds1-log commands provide
performance measurements on a DS1 link. The ds1 option provides a summary
report while the ds1-log option provides a detailed report.
The performance measurements of a DS1 link indicate the quality of the DS1's
physical interface between the system and a far-end system.
The list measurements ds1-facility command provides link performance
measurements on a DS1 Converter facility.
The DS1 Converter complex consists of two DS1Cs connected by one to four
DS1 facilities. This complex allows the distance between two port networks to
extend up to 100 miles, thereby extending the range of the optical fiber link within
limited bandwidth (96 channels). A DS1C complex can be used in a direct
connectivity configuration or a Center Stage Switch configuration. The DS1
converters may be connected to an Expansion Interface (EI) or a Switch Node
Interface (SNI) via a metallic connection.
Parameters
UUCSS
The location of a DS1 converter facility where UUCSS is the location of the circuit
pack and f is a letter (a-d) designating one of the four DS1 facilities.
Examples
list measurements ds1 2a18
list measurements ds1-log 2e01a
list measurements ds1-fac summary 2e01d schedule
Output
The following output examples show all of the four different DS1 reports.
7-188
Issue 1 May 2002
555-233-143