Output
The following example shows the output from the list measurements clan ppp
command.
list measurements clan ppp 1C1001
Switch Name:
sierra
C-LAN PPP PERFORMANCE MEASUREMENT DETAILED REPORT
Date
Time
02/01
03:08
02/01
02:53
02/01
02:38
02/01
02:23
02/01
02:08
Field Descriptions
The date that the data was collected
Date
The current 15-minute interval in which the action was performed
Time
The error count for CRC errors
CRC Check
Total value of the board counter.
Total
The difference between the current and the previous sample
Delta
The number of invalid frames detected. Invalid frames are the frames that
Invalid Frame
are misaligned.
The number of failed attempts for ppp authentication
CHAP Failures
7-184
Issue 1 May 2002
CRC Check
Total
Delta
85
25
60
60
N/A
N/A
1000060
10
1000090
1000050
1000050
1000080
NOTE:
The counter value can be up to 7 digits long because the 16- bit
counter on the board. After the occurrence of an "N/A" the delta
equals the total. Busying out or releasing a board or a port, using the
reset board command, and reseating the board all clear the firmware
counters.
Invalid Frame
Total
Delta
185
85
100
100
N/A
N/A
10
1000080
Page 1 of x
Date:02/02/1999
CHAP Failures
Total
'Delta
5
0
5
5
N/A
N/A
25
5
20
20