Maintenance Commands
Table 7-16. Denied IP events — Continued
Event
Type
Event Description
1936
IP RRJ-Invld RO
anlg stn
1937
IP RRJ-RemOfc not
admin
1938
IP RRJ-Immediate
re-reg
1939
IP RRJ-Failure
moving ext
1940
IP RRJ-Duplicate ext
1941
IP KA-from invld
endpt ID
1942
IP KA-from unreg
user
1943
IP-KA-from unreg
SigGrp
1944
IP RRJ-PSA merge
failure
1945
IP RRJ-New IP user
fail
1946
IP RRJ-PSA merge
failure
1947
IP RRJ-PSA
unmerge fail
7-124
Issue 1 May 2002
Explanation
Registration rejected: invalid
analog station type.
Registration rejected: Remote
Office endpoint
is not administered or
is of unknown station type
Immediate re-registration is
rejected when a registration or
unregistration is in progress for an
extension.
Registration rejected: failure while
trying to force the unregistration of
an extension in the process of
moving it to another port.
Registration rejected as a
duplicate extension.
Keep Alive registration request
rejected: invalid endpoint
identifier.
Keep Alive registration request
rejected: unregistered extension.
Keep Alive registration request
rejected: unregistered signaling
group.
Registration rejected: PSA merge
failure (internal software error).
Registration rejected: failure to
construct new H.323 or IP
Softphone user (internal software
error.) First value is NULL.
Second value is IP address.
Registration rejected: PSA merge
operation failed (internal software
error).
Registration rejected: PSA
unmerge operation failed (internal
software error).
Event
Event
Data 1
Data 2
UID
IP address
UID
IP address
UID
IP address
UID
IP address
UID
IP address
Endpoint
IP address
UID
Endpoint
IP address
UID
Endpoint
IP address
UID
UID
IP address
0
IP address
0
IP address
UID
IP address
Continued on next page