Table 7-16. Denied IP events — Continued
Event
Type
Event Description
1922
IP RRJ-TTI or RO
inactive
1923
IP RRJ-No E164
number
1924
IP RRJ-No GRQ msg
rcvd
1925
IP RRJ-RQ: new LM
fail
1926
IP
RRJ-Authentication
fail
1927
IP RRJ-Invld station
type
7-122
Issue 1 May 2002
Explanation
Registration for an IP set with TTI
service rejected. Possible causes:
TTI is not enabled on the
System Parameters Customer
Options screen.
Remote Office is not enabled
on the System Parameters
Feature Options screen.
Registration rejected; no valid
E.164 phone number available.
The extension is not administered.
Registration rejected; did not
receive a Gatekeeper Request
message
Registration rejected; failure
creating a new Login Manager.
Possible cause:
No available heap memory to
create LoginMgr
Cannot start LoginMgr timer
Clock not set
Registration rejected:
authentication failure. The
password that the user entered
and the administered password on
the station screen do not match.
Registration rejected:
invalid set type
no Remote Office or IP
Softphone administration on
the station screen
Event
Event
Data 1
Data 2
0
IP address
UID
IP address
UID
IP address
UID
IP address
UID
IP address
UID
Type
Continued on next page