Maintenance Commands
Terminating Trunk Transmission Test (Extension)
Test Type 100
Test Type 102
Test Type 105
ISDN Maintenance
ISDN-PRI
Test
Call Extension
ISDN-BRI
Service SPID
7-80
Issue 1 May 2002
This field specifies extensions assigned to receive tie-trunk calls from other
switches that have test line origination capability. The system responds by
sending a sequence of test tones. Test type 100 tests far-end to near-end
loss and C-message by sending:
5.5 seconds of 1004-Hz tone at 0 dB
Quiet until disconnect; disconnect is forced after 1 minute
Test Type 102 tests far-end to near-end loss by sending:
9 seconds of 1004-Hz tone at 0 dB
1 second of quiet
This cycle is repeated until disconnect; disconnect is forced after 24
hours.
Test Type 105 tests 2-way loss, gain slope, and C-message and C-notch
noise by sending:
9 seconds of 1004-Hz tone at -16 dB
1 second of quiet
9 seconds of 404-Hz tone at -16 dB
1 second of quiet
9 seconds of 2804-Hz tone at -16 dB
30 seconds of quiet
½ second of 2225-Hz test progress tone
approximately 5 seconds of quiet
forced disconnect
This field indicates the extension used by far-end ISDN nodes to place calls
to the system, for testing ISDN-PRI trunks between the far end and the
system.
This field shows if the link associates with the Service SPID. If the link is
associated with the Service SPID. This number is the test SPID (0 –
99999) (under BRI-SET MO). Otherwise, this field is blank. Service SPID
is a feature used by the system technician to check building wiring between
the switch and the BRI endpoint.
Continued on next page
555-233-143