Alarm Data Reading Command; Error Code - YASKAWA DX100 Instructions Manual

Options; for high-speed ethernet server function
Hide thumbs Also See for DX100:
Table of Contents

Advertisement

162529-1CD
DX100

3.3.1 Alarm Data Reading Command

Command No.
0x70
Instance
Specify one out of followings
1: The latest alarm
2: The second alarm from the
latest
3: The third alarm from the latest
4: The fourth alarm from the latest
Attribute
Specify one out of followings
1: Alarm code
2: Alarm data
3: By alarm type
4: Alarm occurring time
5: Alarm character string name
Service
Get_Attribute_Single: 0x0E
Get_Attribute_All: 0x01
Status
Respond by one in the followings
0x00 : respond normally
Other than 0x00
Added status
0: not specified
size
1: 1 WORD
2: 2 WORD
Added status
Error code specified by the added
status size
3
Transmission Procedure
3.3 Respective Commands for Robot Control
Request
Sub header part
Data part
No data part
Answer
Sub header part
: respond abnormally
3-20
<Details>
Up to four alarms are displayed on the P.P display at
the same time. Specify one out of them.
Alarm code means the alarm No.
Alarm data means the sub code which supports the
alarm contents. Some alarms may not appear as the
sub code.
Specify the accessing method to the data.
0x0E: Read out data of the specified element number
0x01: Read out data of all the element number
(In this case, specify0 to the element number.)
<Details>
"1" indicates 1 WORD of added status data, and "2"
indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status
code is "1" and that of 2 WORD exists if the code is "2".
HW1480958