Avaya S8700 Maintenance Manual page 1875

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

M/T-ANL (Maintenance/Test Analog Port)
Table 8-473. Test #13 Analog Port Digital Loop-Around Test — Continued
Error
Test
Code
Result
Description / Recommendation
7
FAIL
Conference test failed on the primary information channel.
1. Run the circuit pack tests to check the Tone-Clock (TONE-BD) circuit pack
2. Resolve any problems that are detected on the Tone-Clock (TONE-BD)
3. If the Tone-Clock and Tone Detector circuit packs are functioning properly,
14
FAIL
The primary information channel is not transmitting properly. User may not
notice any interruption in service or may not be able to use this port.
1. Run the circuit pack tests to check the Tone Generator circuit pack and the
2. Resolve any problems that are detected on the Tone Generator circuit pack
3. If the Tone Generator and Tone Detector circuit packs are functioning
PASS
The Maintenance/Test analog port analog trunk testing capability is operating
correctly.
555-233-143
and the Tone Detector circuit pack via the test board UUCSS command.
circuit pack or Tone Detector circuit pack. See the section on Tone
Generator circuit pack.
and the test still fails, replace the Maintenance/Test circuit pack.
Tone Detector circuit pack using test board UUCSS.
or Tone Detector circuit pack. See the section on Tone Generator circuit
pack.
properly, and the test still fails, replace the Maintenance/Test circuit pack.
Continued on next page
Issue 1 May 2002
8-1153