Avaya S8700 Maintenance Manual page 1880

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Hardware Error Log Entries and Test to Clear
Values
Maintenance/Test Board Error Log Entries
Error
Aux
Type
Data
Associated Test
2
0
0
Any
1(a)
0
SAKI Sanity test (#53)
18(b)
0
busyout board
36(c)
0
217(e)
257(d)
0
CC Loop test (#52)
267(e)
513(f)
4352
to
4357
769(g)
4358
1025(h)
4363
NPE Audit test (#50)
1538(i)
0
3840(j)
4096
to
4101
3999 (k)
Any
None
1.
Major or Minor alarms on this MO may have been downgraded to Warning alarms based on the values used in
the set options command.
2.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
Notes:
a. This error indicates that the circuit pack has stopped functioning. Reset the
circuit pack via busyout board UUCSS, reset board UUCSS, and release
board UUCSS commands. If the SAKI Sanity test (#53) passes, then the
on-board circuitry is healthy. If the SAKI Sanity test (#53) fails, replace the
circuit pack.
b. The circuit pack has been busied out via the busyout board UUCSS
command. Execute release board UUCSS command.
c. A port processor on the circuit pack failed to initialize. Reset the circuit
pack via busyout board UUCSS, reset board UUCSS, and release
board UUCSS. if the problem does not go away, replace the circuit pack.
8-1158
Issue 1 May 2002
Alarm
On/Off
1
Level
Board
Test to Clear Value
Any
Any
test port UUCSSpp sh r 1
MINOR
ON
See footnote a
WARNING
OFF
release board UUCSS
WARNING
ON
MINOR
ON
test board UUCSS r3
WARNING
ON
test board UUCSS l
MINOR
ON