2 Parameters
2.1 Overview of parameters
Dynamic index
For parameters with a dynamic index [0...n], the following information is specified here:
• Data set (if available).
• Parameter for the number of indices (n = number - 1).
The following information can be contained in this field:
• "CDS, p0170" (Command Data Set, CDS count)
• "DDS, p0180" (Drive Data Set, DDS count)
• "EDS, p0140" (Encoder Data Set, EDS count)
• "MDS, p0130" (Motor Data Set, MDS count)
• "PDS, p0120" (Power unit Data Set, PDS count)
• "p2615" (traversing blocks count)
Function diagram
The parameter is included in this function diagram. The structure of the parameter function and
its relationship with other parameters is shown in the specified function diagram.
P-Group (only when accessing via BOP (Basic Operator Panel))
Specifies the functional group to which this parameter belongs. The required parameter group
can be set via p0004.
Note
Parameter p0004 is CU-specific (belongs to the Control Unit).
Unit, unit group and unit selection
The standard unit of a parameter is specified in square brackets after the values for "Min",
"Max", and "Factory setting".
For parameters where the unit can be switched over, the specifications for "Unit group" and
"Unit selection" determine the group to which this parameter belongs and with which parameter
the unit can be changed over.
Example:
Unit group: 7_1, unit selection: p0505
The parameter belongs to unit group 7_1 and the unit can be changed over using p0505.
24
Example:
p1070[0]  main setpoint [command data set 0]
p1070[1]  main setpoint [command data set 1], etc.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A