Siemens G130 List Manual page 1215

Hide thumbs Also See for G130:
Table of Contents

Advertisement

24 V DC To the next device
X524.+
X524.+
+
X524.M
P24
X524.M
M
X514.+
+
X514.+
P24_1
X514.M
M1
X514.M
X531.1
X531.2
X531.3
X531.6
X531.4
X531.5
X531.7
X531.8
X532.1
X532.2
X532.7
X532.3
X532.4
X532.8
X532.5
X532.6
X532.9
X532.10
1
2
DO: TM54F_MA, TM54F_SL
SI TM54F - Failsafe Digital Input (F-DI 5 ... F-DI 9)
+24 V electronic
M
M
+24 V
M1
M1
L2+
DI 10
p10040.5
M1
DI 11+
0
DI 11-
1
1
DI 12
p10040.6
M1
DI 13+
0
DI 13-
1
1
M1
DI 14
p10040.7
M1
DI 15+
0
DI 15-
1
1
DI 16
p10040.8
M1
DI 17+
0
DI 17-
1
1
DI 18
p10040.9
M1
DI 19+
0
DI 19-
1
1
M1
3
4
SI F-DI-Um t
1.00...2000.00 [ms]
p10002 (500.0)
r10051.5 (SL)
=1
r10051.5 (MA)
r10051.6 (SL)
=1
r10051.6 (MA)
=1
r10051.7 (SL)
r10051.7 (MA)
r10051.8 (SL)
=1
r10051.8 (MA)
r10051.9 (SL)
=1
r10051.9 (MA)
5
6
fp_2894_51_eng.vsd
06.07.15 V04.08.00
1000 μs
T
0
F35151
"Discrepancy error"
F-DI 5
[2900.1]
&
[2905.1]
T
0
F35151
"Discrepancy error"
F-DI 6
[2900.1]
&
[2905.1]
T
0
F35151
"Discrepancy error"
F-DI 7
[2900.1]
&
[2905.1]
T
0
F35151
"Discrepancy error"
F-DI 8
[2900.1]
&
[2905.1]
T
0
F35151
"Discrepancy error"
F-DI 9
[2900.1]
&
[2905.1]
F-DI: Failsafe Digital Input