status isdn-testcall
status isdn-testcall
This command displays the progress of an outgoing ISDN-PRI test call. The
status screen shows the tested ISDN-PRI B-channel port number, bit error rate,
number of bits transmitted, block error rate, number of blocks transmitted, start
time, duration specified, duration of test call and reason of termination.
Action/Object
Qualifier
status
group
isdn-testcall
number
group
member
number
print
Feature Interactions
If the bit error rate or block error rate is greater than zero, the ISDN-PRI trunk may
be in trouble. The statistical information displayed on the terminal may deactivate
the ISDN trunk. This is subjective because the ISDN trunk may be used for data
or voice. If the trunk is used for data and the rates are high, the trunk should be
deactivated. If the trunk is used for voice, the trunk may not be deactivated. Also,
high rates be at risk for some type of power hit.
Output
The following example shows the output from status idsn-testcall 80/1.
status isdn-testcall 80/1
Bit
Number Block Number
Error Of
Port
Rate
Bits
1B1401
0EE0
4EE7
555-233-119
Qualifier Description
Administered trunk group number
Administered group number (trunk
within a trunk group)
Report sent to printer
ISDN TESTCALL STATUS
Error Of
Start
Rate
Blocks Time
0EE0
6EE2
25/12:36 120
Logins
Default
init
none
inads
craft
Page 1 of
1
SPE A
Duration
Reason
Duration
Of
Of
Specified Test
Termination
100
in progress
Issue 5 October 2002
Feature Interactions
see below
487
Need help?
Do you have a question about the DEFINITY Server CSI and is the answer not in the manual?
Questions and answers