Section 6 ROM
Table 6.21 Status Read Mode Return Codes
Pin Name
Initial Value
I/O7
0
I/O6
0
I/O5
0
I/O4
0
I/O3
0
I/O2
0
I/O1
0
I/O0
0
6.10.7
Status Polling
1. The I/O7 status polling flag indicates the operating status in auto-program/auto-erase mode.
2. The I/O6 status polling flag indicates a normal or abnormal end in auto-program/auto-erase
mode.
Table 6.22 Status Polling Output Truth Table
I/O7
I/O6
0
0
1
0
1
1
0
1
Rev. 6.00 Aug 04, 2006 page 198 of 680
REJ09B0145-0600
Indications
1: Abnormal end
0: Normal end
1: Command error
0: Otherwise
1: Programming error
0: Otherwise
1: Erasing error
0: Otherwise
1: Over counting of writing or erasing
0: Otherwise
1: Effective address error
0: Otherwise
I/O0 to 5
0
0
0
0
Status
During internal operation
Abnormal end
Normal end
—