Maintenance-Object Repair Procedures
Table 8-495. Test #175 Data Module Internal Loop-Around Test — Continued
Error
Test
Code
Result
Description / Recommendation
2500
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
Data received from remote loop back does not match data sent.
1. Check for faulty wiring.
2. Replace the data module and repeat the test.
3. If the test fails, replace the Digital Line circuit pack associated with the data
PASS
Data Module Loop-around test passed.
8-1212
Issue 1 May 2002
module and repeat the test.
Continued on next page
555-233-143