6 Avaya MultiVantage Software-Controlled Maintenance:
Table 16. TEST #36 Port Audit Update Test
Error
Code
Any

DIG-LINE (Digital Line)

Table 17. DIG-LINE (Digital Line)
MO Name (in
Alarm Log)
DIG-LINE
DIG-LINE
Note: You must consult local records for the location and designation of the equipment
rack where the G700 is mounted.
DIG-LINE maintenance monitors and tests ports on digital line Media Modules and the hardware
connected to those ports for lines administered as a digital station. These include stations with just a
digital voice terminal and stations with a digital voice terminal and a linked data module. Media
Gateway-level maintenance is covered by "MG-DCP" whose strategy is described in the "XXX-BD
(Common Port Media Module)" section.
Digital line maintenance interacts with digital line Media Module (MG-DCP) maintenance, and
results of DIG-LINE testing can be affected by the health of the digital line Media Module. Keep this
in mind when investigating digital line problems. There are instances where the service state of a
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
Test
Description/ Recommendation
Result
NO
The test could not relate the internal ID to the port.
BOARD
Check to ensure that the board translations are correct. Translate
the board, if necessary.
Issue the busyout board command.
Issue the reset board command.
Issue the release busy board command.
Issue the test board command. This should re-establish the
linkage between the internal ID and the port.
If the problem persists, replace the circuit pack.
Alarm Level
MINOR
WARNING
Initial Command to Run*
test port GGGVSpp l
test port GGGVSpp sh
DIG-LINE (Digital Line)
Full Name of MO
Digital Line
Digital Line