PE-BCHL (PRI Endpoint Port)
Table 8-498. Test #6 NPE Crosstalk Test — Continued
Error
Test
Code
Result
Description / Recommendation
2020
ABORT
The test did not run due to an existing error on the specific port or a more
general circuit pack error.
1. Examine the Error Log for existing errors against this port or the circuit
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Any
FAIL
The NPE of the tested port was found to be transmitting in error. This will
cause noisy and unreliable connections. The PE-BCHL is moved to
out-of-service/near-end state.
1. Replace the circuit pack.
PASS
The port can communicate over the TDM bus.
555-233-143
pack, and follow recommended procedures.
Continued on next page
Issue 1 May 2002
8-1223