OPS-LINE (DS1 Off-Premises Station Line)
Table 8-486. Test #7 Conference Circuit Test — Continued
Error
Test
Code
Result
Description / Recommendation
PASS
The port can correctly conference multiple connections. User-reported troubles
on this port should be investigated using other port tests and by examining
station, trunk, or external wiring.
0
NO
The test could not relate the internal ID to the port (no board). This could be
BOARD
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
2. If the board was found to be correctly inserted in step 1, issue the busyout
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the linkage
555-233-143
config command, and resolve any problems that are found.
board command.
between the internal ID and the port. If this is not the case, dispatch to
check to ensure that there is a valid board inserted.
Continued on next page