Avaya S8700 Maintenance Manual page 1898

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Hardware Error Log Entries and Test to Clear
Values
M/T-PKT Error Log Entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
1 (a)
41018
none
18 (b)
0
busyout port UUCSSpp
257 (c)
Any
none
513 (d)
Any
Packet Bus Port Health
Inquiry test (#567)
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
Notes:
a. This error indicates a hardware failure with the port circuitry which provides
the packet-bus maintenance functions. Replace the Maintenance/Test
circuit pack if the alarm is not resolved by the test command above.
b. The port has been busied out via the busyout port UUCSSpp command.
c. This error indicates that the Maintenance/Test packet-bus port has
reconfigured the packet bus by swapping a bad lead to a spare. Note that
this error is sent up whenever the Maintenance/Test packet-bus port is
initialized (since the packet-bus port reconfigures the packet bus to
whatever state it determines the packet bus is in). This will occur if the
circuit pack is inserted, if the system is restarted, or if the port is released
from a busyout state. Therefore, it is normal for this error to be present in
the error log.
If the M/T-PKT reconfigures the packet bus 6 times within 15 minutes, a
Minor alarm is raised indicating that either:
8-1176
Issue 1 May 2002
Alarm
Level
Any
MINOR
WARNING
MINOR
MINOR
Packet-bus maintenance functions are not operating correctly
Many changes are taking place on the packet bus (insertions or
removals of circuit packs)
On/Off
Board
Test to Clear Value
Any
test port UUCSSpp
ON
test port UUCSSpp l r 3
OFF
release port UUCSSpp
ON
ON
test port UUCSSpp r 3
555-233-143