Avaya S8700 Maintenance Manual page 1906

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Error Log Entries and Test to Clear Values
Table 8-484. DS1 OPS Maintenance Error Log Entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
15(a)
Any
Audit and Update test
(#36)
18(b)
0
busyout station ext
130(c)
None
1281
Conference Circuit test
(#7)
1537
NPE Crosstalk test (#6)
1793(d)
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
Notes:
a. This is a software audit error that does not indicate any hardware
malfunction. Run the short test sequence, and investigate associated
errors (if any).
b. The DS1 OPS Line has been busied out by a busyout station ext
command. No calls can be made on this line.
c. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
d. Error Type 1793 indicates a problem with the DS1 Interface circuit pack.
Since there is no error against the OPS-LINE port, no alarm is raised
against the OPS-LINE port. However, there should be errors logged
against the DS1 Interface circuit pack. Look for DS1-BD/UDS1-BD errors
in the Hardware Error Log, and follow the appropriate procedures provided
in the
8-1184
Issue 1 May 2002
Alarm
Level
Any
WARNING
WARNING
MINOR
MINOR
''DS1-BD (DS1 Interface Circuit Pack)'' on page
On/Off
Board
Test to Clear Value
Any
test station ext
OFF
release station ext
ON
test station ext
ON
test station ext l r 4
ON
test station ext l r 3
test board UUCSS l
8-586.
555-233-143

Advertisement

Table of Contents
loading