Table 8-493. Test #13 Information and Control Channel Local Loop Test — Continued
Error
Test
Code
Result
Description / Recommendation
1004
ABORT
The port was seized by a valid call during the test. The test has been aborted.
1. Use the display port UUCSSpp command to determine the data module
2000
ABORT
Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2500
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
7
FAIL
Conference test failed on the primary information channel. In some cases,
user may not notice disruption in service. In extreme cases, conferencing
feature may not work at all.
14
FAIL
The primary information channel is not transmitting properly. User impact may
range from noticing nothing to not being able to use this port.
15
FAIL
The control channel between the processor and Digital Line circuit pack is not
transmitting properly. This can cause a wide range of effects. The user may
notice nothing or the port may be totally unusable. This could also disrupt other
users.
1. Run circuit pack tests to check the Tone Generator and the Tone Detector
2. Resolve any problems that are detected on the Tone Generator circuit pack
3. If the Tone Generator and Tone Detector circuit packs are functioning
16
FAIL
The secondary information is not transmitting properly. This can cause a wide
range of effects. The user may notice nothing or the port may be totally
unusable.
1. To be sure that this is not an intermittent problem, repeat this test up to up
2. If complaints still exist (poor data transmission), examine the data module,
PASS
Information and Control Channel Local Loop test passed. Every channel is
transmitting properly.
8-1206
Issue 1 May 2002
extension. Then use status data module command with the extension
number to determine the service state of the data module. If the data
module is in use, wait until the port is idle before retesting.
circuit packs using the test board UUCSS short command.
or Tone Detector circuit pack.
properly, and the test still fails, replace the Digital Line circuit pack.
to 10 times to make sure it continues to pass.
connections, and wiring.
Continued on next page