M/T-PKT (Maintenance/Test Packet Bus Port)
Packet Bus Port Health Inquiry Test (#567)
This test verifies that the packet-bus fault-detection and maintenance function of
the M/T-PKT is functioning properly. This is done by having the M/T-PKT perform
a self-test. If the self-test passes, then the Packet Bus Port Health Inquiry test
passes. If the self-test fails or the Avaya MultiVantage™ software cannot
communicate with the M/T-PKT, then the test fails
Table 8-483. Test #567 Consistency Test
Error
Test
Code
Result
Description / Recommendation
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
System resources necessary to run this test are not available.
2500
ABORT
An internal operation failed, and the test could not be completed.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
2059
FAIL
The M/T-PKT has reported a failure of the on-board self-test.
2060
FAIL
The M/T-PKT has reported an invalid state for the packet bus.
2061
FAIL
The Avaya MultiVantage™ software cannot communicate with the M/T-PKT,
but can communicate with the Maintenance/Test circuit pack.
1. Retry the command.
2. If the test continues to fail, replace the Maintenance/Test circuit pack, and
3. If the test continues to fail,
PASS
The M/T-PKT packet-bus fault-detection capability is operating correctly.
555-233-143
retry the command.
determine whether the M/T-PKT failure is being caused by a packet-bus
fault.
see''PKT-BUS (Packet Bus)'' on page 8-1230