OPS-LINE (DS1 Off-Premises Station Line)
Table 8-486. Test #7 Conference Circuit Test — Continued
Error
Test
Code
Result
Description / Recommendation
1020
ABORT
The test did not run due to an already existing error on the specific port or due
to a more general error on the circuit pack.
1. Examine the error log for existing errors against this port or the circuit pack
2000
ABORT
The test was aborted because response to the test was not received within the
allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test aborts with error code 2000 again, run short test sequence on
2100
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
555-233-143
and attempt to diagnose the already existing error. (Error code 1793
indicates a problem with the DS1 interface board, and any problems on the
associated DS1-BD or UDS1-BD should be resolved first.)
the associated DS1-BD or UDS1-BD. If tests 138 through 145 on the
associated DS1-BD or UDS1-BD are also aborting with error code 2000,
hyperactivity on the board or facility is indicated. In this case, the
hyperactivity problem should be dealt with first.