PE-BCHL (PRI Endpoint Port)
Table 8-496. PRI Endpoint Port Service States
Service
1
State
Alarm
OOS/NE
Warning
Minor
OOS/FE
Warning
Warning
OOS/FE
PINS
MTC/NE
MTC/FE
Warning
Warning
Warning
MTC/FE
PINS
555-233-143
Possible Cause
Port has been busied out by
command.
NPE Crosstalk test (#6)
failed.
UDS1 circuit pack lost its
signal.
Far-end problems or
incompatibility
The far-end port is busied
out.
Service message was sent
and the switch is waiting up
to 2 minutes for a reply from
the far-end terminal adapter.
System link demand busied
out
Signaling channel has been
down for over 90 sec.
Repeated failure of far end
to respond to messages.
The far-end port is being
tested.
Service message was sent,
and the switch is waiting up
to 2 minutes for a reply from
the far-end terminal adapter.
Possible Solution
Enter release pri-endpoint extension.
Replace UDS1 circuit pack.
Is the UDS1 circuit pack removed? Is the
UDS1 cable disconnected? Is the far-end
terminal restarting or experiencing
problems? Check circuit pack using
procedures UDS1-BD.
Check administration and status of the
corresponding port on the terminal
adapter.
Check the status of the far-end terminal
adapter.
Wait 2 minutes, and check service state
after the PINS state has cleared.
Check link status. Release with release
link link#.
Consult ISDN-SGRP, ISDN-LNK and/or
SYS-LINK. Far-end terminal adapter may
currently be restarting.
Maintenance software will periodically try
to resend messages. You can speed the
process with test port UUCSSpp (Test
#256).
Check status of the far-end terminal
adapter.
Wait 2 minutes, and check service state
after the PINS state has cleared.
Continued on next page
Issue 1 May 2002
8-1217