Cambium Networks PTP 820 Series User Manual page 559

Split-mount system
Hide thumbs Also See for PTP 820 Series:
Table of Contents

Advertisement

Chapter 9: TDM Services and Interfaces
To add an MD:
1
In the Select a slot field, select the TDM card to which you want to add the MA.
2
Click Add. The Service OAM Maintenance Association – Add page opens.
Figure 327 Service OAM Maintenance Association – Add Page
3
In the Maintenance Association ID field, select a unique ID to identify the MA.
4
Optionally, in the Maintenance Association Name field, enter a name for the MA, for information purposes.
5
In the Maintenance Domain ID field, select an MD to which the MA belongs.
6
In the Local MEP ID field, select a unique ID for the local MEP.
7
In the Remote MEP ID field, select a unique ID for the remote MEP.
8
In the VLAN Type field, select the outer VLAN type assigned to the tunnel to which the MA will be attached.
Options are:
o
None
o
C-type
o
S-type
This should be the same as the VLAN Type for the service being monitored.
9
In the VLAN ID field, select the VLAN assigned to the tunnel to which the MA will be attached. This should
be the same as the VLAN of the service being monitored.
10
In the CCM Interval field, select the interval (in ms) at which the MA sends CCM messages. Options are:
o
3.3 ms
o
10 ms
o
100 ms
o
1 second
o
10 seconds
o
1 minutes
Configuring Advanced Pseudowire Parameters
phn-3965_006v002
Page 9-51

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ptp 820fPtp 820g

Table of Contents