Chapter 11: Access Management and Security
Figure 362 Access Control User Accounts - Add Page
3.
In the User name field, enter a user name for the user. The user name can be up to 32 characters.
4.
In the Profile field, select a User Profile. The User Profile defines the user's access levels for functionality
groups in the system. See
5.
In the Password field, enter a password for the user. If Enforce Password Strength is activated (see
Configuring the Password Security
o
Password length must be at least eight characters.
o
Password must include characters of at least three of the following character types: lower case letters,
upper case letters, digits, and special characters. For purposes of meeting this requirement, upper case
letters at the beginning of the password and digits at the end of the password are not counted.
o
A password cannot be repeated within five changes in password.
6.
In the Blocked field, you can block or unblock the user. Selecting Yes blocks the user. You can use this
option to block a user temporarily, without deleting the user from the system. If you set this option to Yes
while the user is logged into the system, the user will be automatically logged out of the system within 30
seconds.
Note
Users can also be blocked by the system automatically. You can unblock the user by selecting No in
the Blocked field. See
7.
Optionally, in the Expiration date field, you can configure the user to remain active only until a defined
date. After that date, the user automatically becomes inactive. To set an expiration date, click the calendar
icon and select a date, or enter a date in the format dd-mm-yyyy.
In addition to the configurable parameters described above, the Access Control User Accounts page displays the
following information for each user:
o
Login Status – Indicates whether the user is currently logged into the system.
o
Last Logout – The date and time the user most recently logged out of the system.
Configuring User
Profiles.
Parameters), the password must meet the following criteria:
Configuring the General Access Control Parameters.
phn-3965_006v002
Page 11-10
Configuring Users