Chapter 5: Radio Configuration
Power Status
Admin Status
Power Admin
Media Type
Read-only. Indicates whether the IDU is supplying PoE power to
the RFU. Possible values are:
Supplying – PoE power is being supplied to the RFU via the
PTP 820F
Detecting – Usually, this indicates a transient state
immediately after connecting the RFU to the IDU. If it lasts
for more than about one second, it indicates that there is no
power consumption, usually because the RFU is not properly
connected to the IDU.
Fault – PoE power to the RFU is disabled due to a hardware
failure, usually a short circuit.
Disable – The Power Admin field is set to Disable.
The configured status of the RFU connected to the PTP 820F. By
default, the status is Enabled.
Determines whether the IDU supplies PoE power to the RFU. By
default, Power Admin is Enabled.
The interface type on the PTP 820F connected to the RFU. The
default value is RJ45.
phn-3965_006v002
Page 5-9
Configuring the IDU-RFU Connection (PTP 820F only)