Chapter 7: Quality of Service (QoS)
3.
In the Policer profile field, select a profile from the policer profiles defined in the system. The Policer profile
drop-down list includes the ID and description of all defined profiles.
4.
In the Unicast admin field, select Enable to enable policing on unicast traffic flows from the logical
interface, or Disable to disable policing on unicast traffic flows from the logical interface.
5.
Click Apply.
Assigning Multicast Policers
To assign a policer for multicast traffic to a logical interface:
1.
Select Ethernet > Interfaces > Logical Interfaces. The Logical Interfaces page opens
2.
Select the interface in the Ethernet Logical Port Configuration table and click Policers. The Policers page
opens. By default, the Policers page opens to the Unicast Policer table
3.
Select Multicast Policer. The Multicast Policer table appears.
Figure 227 Logical Interfaces – Policers Page – Multicast Policer
4.
In the Policer profile field, select a profile from the policer profiles defined in the system. The Policer profile
drop-down list includes the ID and description of all defined profiles.
5.
In the Multicast admin field, select Enable to enable policing on multicast traffic flows from the logical
interface, or Disable to disable policing on multicast traffic flows from the logical interface.
6.
Click Apply.
Assigning Broadcast Policers
To assign a policer for broadcast traffic to a logical interface:
1.
Select Ethernet > Interfaces > Logical Interfaces. The Logical Interfaces page opens