Cambium Networks PTP 820 Series User Manual page 460

Split-mount system
Hide thumbs Also See for PTP 820 Series:
Table of Contents

Advertisement

Chapter 8: Ethernet Protocols
4
Optionally, in the ERPI Name field, enter a descriptive name for the ERPI.
5
In the Type field, select the type of ERPI, based on the type of ring:
o
Ring: A Ring is an Ethernet ring that is connected on two ports (East and West service points) to an
interconnection node.
o
Sub-ring: A Sub-Ring is an Ethernet ring which is connected to another ring or network through the use of
interconnection nodes (East and West service points). On their own, the Sub-Ring links do not form a
closed physical loop. A closed loop may be formed by the sub-ring links and the link between
interconnection nodes that is controlled by other ring or network.
o
Ring with sub-ring: The ERPI includes both a ring, with East and West service points, and a connection to a
sub-ring using a Sub-Ring service point.
6
In the Service ID field, select the ID of the Ethernet service to which the ERPI belongs.
7
Optionally, in the MEG Level field, select the Maintenance Entity Group (MEG) level used for R-APS
messages sent in the ERPI (0-7).
8
Click Next. The second page of the Add G.8032 ERPI Attribute wizard opens.
Figure 255 G.8032 ERPI Attribute Wizard – Page 2
9
In the West ERPI port (SP) field, select the first endpoint for the ERPI. This can be any service point that has
been configured for the service.
10
Click Next. The third page of the Add G.8032 ERPI Attribute wizard opens.
phn-3965_006v002
Page 8-5
Configuring G.8032

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ptp 820fPtp 820g

Table of Contents