Chapter 4: Unit Management
Figure 133 Trap Managers - Edit Page
3.
Configure the trap manager parameters, as described in
4.
Click Apply, then Close.
Table 37 Trap Manager Parameters
Parameter
IPv4 Address
IPv6 Address
Description
Admin
Community
Port
Heartbeat Period
CLLI
V3 User Name
Definition
If the IP address family is configured to be IPv4, enter the destination IPv4
address. Traps will be sent to this IP address. See
Version for Initiating
Communications.
If the IP address family is configured to be IPv6, enter the destination IPv6
address. Traps will be sent to this IP address. See
Version for Initiating
Communications.
Enter a description of the trap manager (optional).
Select Enable or Disable to enable or disable the selected trap manager.
Enter the community string for the SNMP read community.
Enter the number of the port through which traps will be sent.
Enter the interval, in minutes, between each heartbeat trap.
Enter a Common Language Location Identifier (CLLI). The CLLI is free text
that will be sent with the trap. You can enter up to 100 characters.
If the SNMP Trap version selected in
Page
page is V3, enter the name of a V3 user defined in the system.
To view or define a V3 user, use the
Note: Make sure that an identical V3 user is also defined on the
manager's side.
phn-3965_006v002
Page 4-10
Table 37 Trap Manager
Parameters.
Defining the IP Protocol
Defining the IP Protocol
Figure 129 SNMP Parameters
Figure 130 V3 Users Page
Configuring Trap Managers
page.