Chapter 3: Configuration Guide
o
dot1q - All C-VLANs and untagged frames are classified into the service.
Note
For a full explanation of Ethernet Services, service types, and attached interface types, see
Configuring Ethernet
6. Click Next. Page 3 of the 1+0 Repeater Quick Configuration wizard opens.
Figure 60 1+0 Repeater Quick Configuration Wizard (PTP 820G) – Page 3
7. For each interface, configure the following radio parameters. The red arrow points to the interface you
are configuring. For example, in
1. In the TX Frequency (MHz) field, set the transmission radio frequency for the first radio in MHz.
2. In the RX Frequency (MHz) field, set the received radio frequency for the first radio in MHz.
3. In the TX Level (dBm) field, enter the desired TX signal level (TSL) for the first radio. The range of values
depends on the frequency and RFU type.
4. To mute the TX output of the RFU, select On in the TX mute field. To unmute the TX output of the RFU,
select Off.
8. Click Next. Page 4 of the 1+0 Repeater Quick Configuration wizard opens.
Service(s).
Figure
60, the user is configuring Radio 1
phn-3965_006v002
Page 3-20
Configuring a Link Using the Quick Configuration Wizard