Chapter 9: TDM Services and Interfaces
o
The maximum number of services (256) has already been configured on the PTP 820G or PTP 820F unit.
Adding a Service between a TDM Port or Protection Group and a
Radio Port, a Radio Group, or an Ethernet or Cascading Interface
1
In the Interface #1 screen of the TDM PseudoWire Services Creation page, configure the parameters of the
service's first endpoint.
2
In the Slot/Group/Port field, select a TDM interface, a radio interface or group, an Ethernet interface, or a
cascading interface.
Configuring a TDM Card or Group as an Endpoint
i
Select the E1/DS1 interface.
Figure 310: Pseudowire Service Creation – Interface #1 E1/DS1
Note
Some interfaces may not appear in the Slot/Group/Port field. Refer to
Endpoints
for the possible reasons an interface will not appear. If there are no available interfaces, a
message appears that no endpoint can be selected.
ii
In the E1/DS1 field, select an E1/DS1 or VC12. This configures the first endpoint for the service.
Note
Only E1/DS1s that are not already assigned to a pseudowire service appear in the selection box. Also,
an E1/DS1 will not appear in the selection box if the TDM interface has already been assigned a
service point with a classification and a slot and port or group number that match the classification
that would automatically be assigned to the E1/DS1 via the TDM PseudoWire Service Creation page.
phn-3965_006v002