Chapter 5: Radio Configuration
Parameter
tx-frequency
local-remote
The following command sets the TX frequency of fixed radio interface 1 to 12900000 KHz, and sets the RX
frequency of the remote unit to the same value.
radio[1/1]>rf set tx-frequency 12900000
The following command sets the TX frequency of fixed radio interface 2 to 12900000 KHz, but does not set the RX
frequency of the remote unit.
radio[1/2]>rf set rx-frequency 12900000 local-remote disable
Configuring the Transmit (TX) Level (CLI)
To set the transmit (TX) level of a radio, enter the following command in radio view:
radio[x/x]>rf set tx-level <tx-level>
To display the maximum transmit (TX) level of a radio, enter the following command in radio view:
radio[x/x]>rf show max-tx-level
Table: Transmit (TX) Level CLI Parameters
Parameter
Input Type
tx-level
Number
The following command sets the TX level of fixed radio interface 1 to 10 dBm:
radio[1/1]>rf set tx-level 10
Configuring the Radio (MRMC) Script(s)
To display Multi-Rate Multi-Constellation PMs, including information on ACM profile fluctuations per interval per
radio:
1.
Select Radio > PM & Statistics > MRMC. The MRMC PM Report page opens.
Figure 174 MRMC PM Report Page
Table 22: Transmit (TX) Frequency CLI Parameters
Input
Type
Number
Variable
Permitted Values
-50-34
phn-3965_006v002
Page 5-37
Configuring and Viewing Radio PMs and Statistics
Permitted
Description
Values
Depends on
The desired TX frequency (in KHz) and, if
the MRMC
<local-remote> is set to enable, the desired
script and
RX frequency of the remote unit.
RFU type.
enable
Optional. Determines whether to apply the
disable
configured TX frequency value to the RX
frequency of the remote unit. By default,
the configured TX frequency value is applied
to the RX frequency of the remote unit.
Description
The desired TX signal level (TSL), in dBm.