Cambium Networks PTP 820 Series User Manual page 808

Split-mount system
Hide thumbs Also See for PTP 820 Series:
Table of Contents

Advertisement

Chapter 17: Radio Configuration (CLI)
To clear all radio PMs in the system, enter the following command in root view:
root> radio pm clear all
To clear defective blocks counters for a radio, go to radio view and enter the following command:
radio[x/x]>modem clear counters
Displaying Excessive BER (Aggregate) PMs (CLI)
You can display modem BER (Bit Error Ratio) PMs in either 15-minute or daily intervals.
To display modem BER PMs in 15-minute intervals, go to radio view and enter the following command:
radio [x/x]>framer pm-aggregate show interval 15min
The following is a partial sample output of the
radio [1/1]>framer pm-aggregate show interval 15min
Modem BER PM table:
===================
Interval Integrity ES SES UAS BBE
===========================================================
0 1 0 0 333 0
1 1 0 0 900 0
2 1 0 0 900 0
3 1 0 0 900 0
4 1 0 0 900 0
5 1 0 0 900 0
6 1 0 0 900 0
7 1 0 0 900 0
8 1 0 0 900 0
radio [1/1]>
To display modem BER PMs in daily intervals, go to radio view and enter the following command:
radio [x/x]>framer pm-aggregate show interval 24hr
The following is a sample output of the
radio [1/1]>framer pm-aggregate show interval 24hr
Modem BER PM table:
===================
Interval Integrity ES SES UAS BBE
===========================================================
0 1 0 0 53843 0
4 1 0 0 37061 0
5 1 0 0 4034 0
6 1 0 0 85971 0
8 1 0 0 46171 0
11 1 0 0 24184 0
15 1 0 0 85978 0
17 1 0 0 54979 0
radio [1/1]>
framer pm-aggregate show interval 15min
framer pm-aggregate show interval 24hr
phn-3965_006v002
Page 17-19
Configuring and Viewing Radio PMs and Statistics (CLI)
command:
command:

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ptp 820fPtp 820g

Table of Contents