Cambium Networks PTP 820 Series User Manual page 427

Split-mount system
Hide thumbs Also See for PTP 820 Series:
Table of Contents

Advertisement

Chapter 7: Quality of Service (QoS)
Table 71 Policer Profile Parameters
Parameter
Profile ID
Description
Policer type
CIR
CBS
EIR
EBS
Color mode
Coupling flag
Editing a Policer Profile
To edit a policer profile, select the profile in the Police Profile table and click Edit. The Policer Profile Table Edit
page opens.
The Policer Profile Table - Edit page is identical to the Policer Profile Table - Add page
parameter that can be configured in the Policer Profile Table Add page, except the Profile ID.
Deleting a Policer Profile
You cannot delete a policer profile that is attached to a logical interface. You must first remove the profile from the
logical interface, then delete the profile. See
To delete a policer profile, select the profile in the Police Profile table and click Delete. The profile is deleted.
Definition
A unique ID for the policer profile. You can choose from any unused value
from 1 to 250. Once you have added the profile, you cannot change the
Profile ID.
A description of the policer profile.
Read-only. The type of policer. Always set to MEF-TRTCM.
Enter the Committed Information Rate (CIR) for the policer, in bits per
second. Permitted values are 0, or 64,000 through 1,000,000,000 bps. If
the value is 0, all incoming CIR traffic is dropped.
Enter the Committed Burst Rate (CBR) for the policer, in Kbytes.
Permitted values are 2 through 128 Kbytes.
Enter the Excess Information Rate (EIR) for the policer, in bits per second.
Permitted values are 0, or 64,000 through 1,000,000,000 bps. If the value
is 0, all incoming EIR traffic is dropped.
Enter the Excess Burst Rate (EBR) for the policer, in Kbytes. Permitted
values are 2 through 128 Kbytes.
Select how the policer treats packets that ingress with a CFI or DEI field
set to 1 (yellow). Options are:
Color Aware – All packets that ingress with a CFI/DEI field set to 1
(yellow) are treated as EIR packets, even if credits remain in the CIR
bucket.
Color Blind – All ingress packets are treated as green regardless of their
CFI/DEI value. A color-blind policer discards any former color decisions.
Select Enable or Disable. When enabled, frames that ingress as yellow
may be converted to green when there are no available yellow credits in
the EIR bucket. Coupling Flag is only relevant in Color Aware mode.
Assigning Policers to
phn-3965_006v002
Page 7-16
Configuring Policers (Rate Metering)
(Figure
225). You can edit any
Interfaces.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ptp 820fPtp 820g

Table of Contents