Cambium Networks PTP 820 Series User Manual page 275

Split-mount system
Hide thumbs Also See for PTP 820 Series:
Table of Contents

Advertisement

Chapter 3: Configuration Guide
Parameter
Automatic delay calibration
status
Note
You can display detailed PMs for the diversity interface and the combined signal. See
for the Combined IF Combining Signal.
Definition
Note:
Manual delay calibration is only utilized for Combined mode.
For automatic delay calibration, click Auto Delay Calibration at the bottom of the IF
Combining - Edit page. The system automatically calibrates the required delay
between the signals from the main and diversity antennas. The Automatic Delay
Calibration Status field displays the system status of the Automatic Delay
Calibration feature. Possible values status values are:
Success – Indicates that the system has successfully calibrated the signal delay
Failure – Indicates that the system cannot automatically calibrate the signal
delay.
No-Action – Indicates that the system has not performed an automatic delay
calibration.
Note:
Automatic delay calibration can only be performed when the system is
error-free and there are no negative weather conditions. In an XPIC link, disable
XPIC and mute the mate unit at the remote side of the link before performing
automatic delay calibration.
phn-3965_006v002
Page 3-117
Configuring HSB Radio Protection
Displaying PMs

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ptp 820fPtp 820g

Table of Contents