Cambium Networks PTP 820 Series User Manual page 884

Split-mount system
Hide thumbs Also See for PTP 820 Series:
Table of Contents

Advertisement

Chapter 19: Quality of Service (QoS) (CLI)
Per frame type (unicast, multicast, and broadcast)
Per frame ethertype
This section includes:
Assigning a Rate Meter (Policer) for Unicast Traffic (CLI)
Assigning a Rate Meter (Policer) for Multicast Traffic (CLI)
Assigning a Rate Meter (Policer) for Broadcast Traffic (CLI)
Assigning a Rate Meter (Policer) per Ethertype (CLI)
Assigning a Rate Meter (Policer) for Unicast Traffic (CLI)
To assign a rate meter (policer) profile for unicast traffic to the interface, go to interface view for the interface and
enter the following command:
eth type eth [x/x]>rate-meter unicast add capability admin-state <admin-
state> profile-id <profile-id>
To change the rate meter (policer) profile for unicast traffic, go to interface view for the interface and enter the
following command:
eth type eth [x/x]>rate-meter unicast edit admin-state <admin-state>
profile-id <profile-id>
To display the current unicast rate meter (policer) profile for an interface, go to interface view for the interface and
enter the following command:
eth type eth [x/x]>rate-meter unicast show configuration
To delete the rate meter (policer) profile for unicast traffic, go to interface view for the interface and enter the
following command:
eth type eth [x/x]>rate-meter unicast delete
Table 228 Assigning Rate Meter for Unicast Traffic CLI Parameters
Parameter
Input Type
admin-state
Variable
profile-id
Number
The following command assigns Rate Meter Profile 1 to unicast traffic on GbE 1, and enables rate metering on the
port:
eth type eth [1/1]>rate-meter unicast add capability admin-state enable
profile-id 1
The following command changes the rate meter (policer) profile for unicast traffic on GbE 1 to 4:
eth type eth [1/1]>rate-meter unicast edit admin-state enable profile-id
4
Permitted Values
Description
enable
Enables or disables rate metering on
unicast traffic flows from the logical
disable
interface.
Select from the rate meter profiles
1 – 250
defined in the system.
phn-3965_006v002
Page 19-17
Configuring Policers (Rate Metering) (CLI)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ptp 820fPtp 820g

Table of Contents