Chapter 10: Synchronization
Parameter
Sync Transmitted
Follow-Up Transmitted
Delay Response Transmitted
Delay Request Transmitted
Announce Received
Sync Received
Follow-Up Received
Delay Response Received
Delay Request Received
Dropped Messages
Lost Messages
Disabling 1588 PTP
To disable 1588 PTP synchronization:
1.
Select Sync > 1588 > Boundary Clock > Port Parameters. The 1588 Boundary Clock – Port Parameters page
opens.
2.
Select an interface and click Edit. The 1588 Boundary Clock – Port Parameters – Edit page opens.
3.
In the Admin field, select Disable.
Note
It is important to disable Boundary Clock on the interfaces before disabling 1588 PTP.
4.
Select Sync > 1588 > General Configuration. The 1588 – General Configuration page opens.
5.
In the 1588 PTP field, select Disable.
6.
Click Apply.
Definition
The number of Sync messages that have been transmitted
from the port.
The number of Follow-Up messages that have been
transmitted from the port.
The number of Delay Response messages that have been
transmitted from the port.
The number of Delay Request messages that have been
transmitted from the port.
The number of Announce messages that have been
received by the port.
The number of Sync messages that have been received by
the port.
The number of Follow-Up messages that have been
received by the port.
The number of Delay Response messages that have been
received by the port.
The number of Delay Request messages that have been
received by the port.
The number of dropped messages.
The number of lost messages.