Chapter 10: Synchronization
Figure 353 1588 Boundary Clock – Clock Advanced Parameters Page
All of the advanced Boundary Clock parameters are read-only. The following Table lists and describes the Boundary
Clock advanced parameters.
Table 116 Boundary Clock Advanced Parameters
Parameter
Steps Removed
Offset from Master (Nanoseconds)
Mean Path Delay (Nanoseconds)
Master Clock Identity
Master Port Number
Grandmaster Identity
Grandmaster Clock Class
Definition
The number of PTP clocks traversed from the grandmaster
to the slave clock in the local PTP 820 Boundary Clock
node. You can define a maximum number of steps in the
Clock Default Parameters page. See Displaying and Setting
the Boundary Clock Default Parameters.
The time difference between the master clock and the
local slave clock (in ns).
The mean propagation time for the link between the
master and the local slave (in ns).
The clock identity of the current master clock.
The clock identity of the current master port.
The clock identity of the current grandmaster.
The clock class of the current grandmaster. The clock class
is one of the elements of the clock quality, as defined in
IEEE-1588.