Chapter 3: Configuration Guide
Figure 126 IF Combining – Edit Page
3. Configure the fields listed in the table below.
4. Click Apply.
Table 34 IF Combining parameters
Parameter
Radio location
Type
IF combiner mode
RSL Connector Source
Diversity RX Level (dBm)
Combined RX Level (dBm)
Delay Calibration Value (nSec)
Definition
Read-only. Identifies the radio carrier.
Read-only. The type of RFU.
Select which radio signal to use:
Main – Only the Main antenna signal is selected.
Diversity – Only the Diversity antenna signal is selected.
Combined – The combined signal from both antennas is selected.
To configure IF Combining, select Combined.
Determines the signal source of the RSL connector for purposes of testing RSL
output during setup or maintenance. Options are:
Main – RSL is taken from the Main radio interface.
Diversity – RSL is taken from the Diversity radio interface.
Note:
PHY1 and PHY2 are not relevant for this version.
Read-only. Displays the RX signal level (RSL) of the Diversity radio interface, in dBm.
Note:
The RX signal level (RSL) of the Main radio interface is displayed in the RX
Level field of the Radio Parameters page.
Read-only. Displays the signal level (RSL) of the Combined signal, in dBm.
Note:
The RX signal level (RSL) of the Main radio interface is displayed in the RX
Level field of the Radio Parameters page.
For manual delay calibration, in the Delay Calibration Value field, enter the
number of nanoseconds to delay between the main and diversity signals.