Chapter 19: Quality of Service (QoS) (CLI)
To delete the rate meter (policer) profile for an Ethertype, go to interface view for the interface and enter one or
more of the following commands:
eth type eth [x/x]>rate-meter ethertype1 delete
eth type eth [x/x]>rate-meter ethertype2 delete
eth type eth [x/x]>rate-meter ethertype3 delete
Table 231 Assigning Rate Meter per Ethertype CLI Parameters
Parameter
Input Type
ethertype#
Variable
ethertype-
Hexadecimal
value
admin-state
Variable
profile-id
Number
The following commands assign Rate Meter Profiles 1, 2, and 3 to Ethertypes 0x8000, 0x8100, and 0x9100,
respectively, on GbE 1, and enable rate metering on the port.
eth type eth [1/1]>rate-meter ethertype1 add capability ethertype-value
0x8000 admin-state enable profile-id 1
eth type eth [1/1]>rate-meter ethertype2 add capability ethertype-value
0x8100 admin-state enable profile-id 2
eth type eth [1/1]>rate-meter ethertype3 add capability ethertype-value
0x9100 admin-state enable profile-id 3
The following commands change the rate meter (policer) profiles assigned in the examples above to 4, 5, and 6,
respectively.
eth type eth [1/1]>rate-meter ethertype1 edit ethertype-value 0x8000
admin-state enable profile-id 4
eth type eth [1/1]>rate-meter ethertype2 edit ethertype-value 0x8100
admin-state enable profile-id 5
eth type eth [1/1]>rate-meter ethertype3 edit ethertype-value 0x9100
admin-state enable profile-id 6
Permitted Values
Description
ethertype1
Identifies which of three possible policer-
per-Ethertype combinations you are
ethertype2
defining.
ethertype3 I
1-65535
Identifies the Ethertype to which the
profile applies.
enable
Enables or disables policing on broadcast
traffic flows from the logical interface.
disable
1 – 250
Select from the policer profiles defined in
the system. For instructions on defining
rate meter (policer) profiles, refer to
Configuring Rate Meter (Policer) Profiles
(CLI).