Chapter 8: Ethernet Protocols

Configuring Timers

You can configure timers per ERPI to control the ERPI's switching and convergence parameters. The following
timers are available:
Wait to Restore (WTR) Timer – Defines a minimum time the system waits after signal failure is recovered
before reverting to idle state.
Guard Time – Prevents unnecessary state changes and loops.
Hold-Off Time – Determines the time period from failure detection to response.
To configure the ERPI timers:
1
Select Ethernet > Protocols > G.8032 > ERPI Attribute. The G.8032 ERPI Attribute page opens
2
Select the ERPI and click Edit. The ERPI Attribute – Edit page opens
3
In the ERPI WTR field, enter the Wait to Restore (WTR) timer (in minutes). The WTR timer is a minimum
time the system waits after signal failure is recovered before reverting to idle state.
4
In the ERPI Guard Time field, enter the ERPI guard time (in msec). You must enter a multiple of 10. The
guard time is the minimum time the system waits after recovery from a signal failure before accepting new
R-APS messages. The purpose of this timer is to prevent unnecessary state changes and loops.
5
In the ERPI Holdoff Time field, enter the ERPI hold-off time (in msec). You must enter a multiple of 100. The
hold-off time determines the time period from failure detection to response.
6
Click Apply, then Close.

Viewing the ERPI Configuration and Status Parameters

The G.8032 ERPI Attribute page
configured in the system.
To display a full list of configuration and status parameters for an ERPI:
1
Select Ethernet > Protocols > G.8032 > ERPI Attribute. The G.8032 ERPI Attribute page opens
2
Select the ERPI and click Edit. The ERPI Attribute – Edit page opens
o
Table 72
lists and describes the parameters in the ERPI configuration section of the ERPI Attribute – Edit
page.
o
Table 73
lists and describes the parameters in the ERPI status section of the ERPI Attribute – Edit page.
Table 72 Attached Interface Types
Parameter
ERPI ID
ERPI Name
ERPI Type
ERPI Service ID
Instance ID
West ERPI Port (SP)
(Figure
253) displays some of the configuration and status parameters for ERPIs
Definition
Read-only. A unique ID that identifies the ERPI.
A descriptive name for the ERPI.
Read-only. The ERPI type.
Read-only. The ID of the Ethernet service to which the ERPI belongs.
Read-only. The MSTI to which the Ethernet service is mapped. See
Ethernet Services to MSTP instances
Read-only. The interface to which the west ERPI service point belongs.
phn-3965_006v002
Page 8-9
(Figure
259).
(Figure
259).
(MSTIs).
Configuring G.8032
(Figure
253).
(Figure
253).