Clock Set Command - ADTRAN 5000 Series Command Reference Manual

Adtran network device command reference guide
Table of Contents

Advertisement

Command Reference Guide
clock set <time> <day> <month> <year>
Use the clock set command to configure the system software clock. For the command to be valid, all fields
must be entered. Refer to the Usage Example below for an example.
Syntax Description
<time>
<day>
<month>
<year>
Default Values
No default value necessary for this command.
Applicable Platforms
This command applies to the NetVanta 300, 1000, 1000R, 2000, 3000, 4000, and 5000 and
Total Access 900 Series units.
Command History
Release 1.1
Usage Examples
The following example sets the system software clock for 3:42 pm, August 22 2004:
>enable
#clock set 15:42:00 22 Au 2004
61200990L1-35E
Sets the time (in 24-hour format) of the system software clock in the format
HH:MM:SS (hours:minutes:seconds).
Sets the current day of the month (valid range: 1 to 31).
Sets the current month (valid range: January to December). You need only enter
enough characters to make the entry unique. This entry is not case-sensitive.
Sets the current year (valid range: 2000 to 2100).
Command was introduced.
Copyright © 2005 ADTRAN
Enable Mode Command Set