PRCM Registers
Table 6-39. RECHARGECFG Register Field Descriptions (continued)
Bit
Field
2-0
PER_E
468
Power, Reset, and Clock Management
Type
Reset
Description
R/W
0h
Number of 32 KHz clocks between activation of recharge controller
For recharge algorithm, PERIOD is the initial period when entering
powerdown mode. The adaptive recharge algorithm will not change
this register
PERIOD will effectively be a 16 bit value coded in a 5 bit mantissa
and 3 bit exponent:
This field sets the Exponent of the Period.
PERIOD=(PER_M*16+15)*2