9.2.1.30 FLASH_P_R_PV Register (Offset = 178h) [reset = 26E0200h]
FLASH_P_R_PV is shown in
Flash Program, Read, and Program Verify
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
PH
R-2h
Bit
Field
31-24
PH
23-16
RH
15-8
PVH
7-0
PVH2
SWCU117C – February 2015 – Revised September 2015
Submit Documentation Feedback
Figure 9-52
and described in
Figure 9-52. FLASH_P_R_PV Register
RH
R-6Eh
Table 9-54. FLASH_P_R_PV Register Field Descriptions
Type
Reset
R
2h
R
6Eh
R
2h
R
0h
Copyright © 2015, Texas Instruments Incorporated
Table
9-54.
9
PVH
R-2h
Description
Program hold time in half-microseconds after SAFELV goes low.
Value will be converted to number of FCLK cycles by the flash
device driver and the converted value is written to
FLASH:FSM_P_OH.PGM_OH when an erase/program operation is
initiated.
Read hold/mode transition time in cycles. Value will be written to the
RD_H field bits[7:0] of the FSM_RD_H register in the flash module
by the flash device driver when an erase/program operation is
initiated.
Program verify hold time in half-microseconds after SAFELV goes
low. Value will be converted to number of FCLK cycles by the flash
device driver and the converted value is written to
FLASH:FSM_PE_VH.PGM_VH when an erase/program operation is
initiated.
Program verify row switch time in half-microseconds.
Factory Configuration (FCFG)
8
7
6
5
4
3
2
1
PVH2
R-0h
Device Configuration