7.8.1.7
EFUSE Register (Offset = 1000h) [reset = 0h]
EFUSE is shown in
Internal. Only to be used through TI provided API.
31
30
29
28
RESERVED
R-0h
15
14
13
12
Bit
Field
31-29
RESERVED
28-24
INSTRUCTION
23-16
RESERVED
15-0
DUMPWORD
SWCU117C – February 2015 – Revised September 2015
Submit Documentation Feedback
Figure 7-16
and described in
Figure 7-16. EFUSE Register
27
26
25
INSTRUCTION
R/W-0h
11
10
9
DUMPWORD
Table 7-10. EFUSE Register Field Descriptions
Type
Reset
R
0h
R/W
0h
R
0h
R/W
0h
Copyright © 2015, Texas Instruments Incorporated
Table
7-10.
24
23
22
21
8
7
6
5
R/W-0h
Description
Internal. Only to be used through TI provided API.
Internal. Only to be used through TI provided API.
Internal. Only to be used through TI provided API.
Internal. Only to be used through TI provided API.
Versatile Instruction Memory System (VIMS)
VIMS Registers
20
19
18
17
RESERVED
R-0h
4
3
2
1
16
0