9.2.1.76 PWD_CURR_95C Register (Offset = 3B0h) [reset = 4C627A3Bh]
PWD_CURR_95C is shown in
Power Down Current Control 95C
31
30
29
28
DELTA_CACHE_REF
15
14
13
12
DELTA_XOSC_LPM
Bit
Field
31-24
DELTA_CACHE_REF
23-16
DELTA_RFMEM_RET
15-8
DELTA_XOSC_LPM
7-0
BASELINE
SWCU117C – February 2015 – Revised September 2015
Submit Documentation Feedback
Figure 9-98
and described in
Figure 9-98. PWD_CURR_95C Register
27
26
25
R-4Ch
11
10
9
R-7Ah
Table 9-100. PWD_CURR_95C Register Field Descriptions
Type
Reset
R
4Ch
R
62h
R
7Ah
R
3Bh
Copyright © 2015, Texas Instruments Incorporated
Table
9-100.
24
23
22
21
DELTA_RFMEM_RET
8
7
6
5
Description
Additional maximum current, in units of 1 µA, with cache retention
Additional maximum current, in 1 µA units, with RF memory retention
Additional maximum current, in units of 1 µA, with XOSC_HF on in
low-power mode
Worst-case baseline maximum power-down current, in units of 0.5
µA
Factory Configuration (FCFG)
20
19
18
17
R-62h
4
3
2
1
BASELINE
R-3Bh
Device Configuration
16
0