Download Print this page

Texas Instruments SimpleLink CC2620 Technical Reference Manual page 513

Zigbee rf4ce wireless mcu simplelink cc13 series; simplelink cc26 series

Advertisement

www.ti.com
6.2.4.38 PDCTL0 Register (Offset = 12Ch) [reset = 0h]
PDCTL0 is shown in
Power Domain Control
31
30
23
22
15
14
7
6
Bit
Field
31-3
RESERVED
2
PERIPH_ON
1
SERIAL_ON
0
RFC_ON
SWCU117C – February 2015 – Revised September 2015
Submit Documentation Feedback
Figure 6-77
and described in
Figure 6-77. PDCTL0 Register
29
28
RESERVED
21
20
RESERVED
13
12
RESERVED
5
4
RESERVED
R-0h
Table 6-82. PDCTL0 Register Field Descriptions
Type
Reset
R
0h
R/W
0h
R/W
0h
R/W
0h
Copyright © 2015, Texas Instruments Incorporated
Table
6-82.
27
26
R-0h
19
18
R-0h
11
10
R-0h
3
2
PERIPH_ON
R/W-0h
Description
Software must not rely on the value of a reserved. Writing any other
value than the reset value may result in undefined behavior.
PERIPH Power domain.
0: PERIPH power domain is powered down
1: PERIPH power domain is powered up
SERIAL Power domain.
0: SERIAL power domain is powered down
1: SERIAL power domain is powered up
0: RFC power domain powered off if also PDCTL1.RFC_ON = 0
1: RFC power domain powered on
Power, Reset, and Clock Management
PRCM Registers
25
24
17
16
9
8
1
0
SERIAL_ON
RFC_ON
R/W-0h
R/W-0h