Interrupts and Events Registers
Table 4-105. GPT3BCAPTSEL Register Field Descriptions (continued)
Bit
Field
6-0
EV
382
Interrupts and Events
Type
Reset
Description
R/W
5Ch
Read/write selection value
0h = Always inactive
4h = Edge detect event from IOC. Configured by the
IOC:IOCFGn.EDGE_IRQ_EN and IOC:IOCFGn.EDGE_DET settings
7h = Event from AON_RTC, controlled by the
AON_RTC:CTL.COMB_EV_MASK setting
Bh = AUX combined event, the corresponding flag register is here
AUX_EVCTL:EVTOMCUFLAGS
15h = FLASH controller error event, the status flags are
FLASH:FEDACSTAT.FSM_DONE and
FLASH:FEDACSTAT.RVF_INT
19h = RFC Doorbell Command Acknowledgment Interrupt,
equivalent to RFC_DBELL:RFACKIFG.ACKFLAG
1Ah = Combined RCF hardware interrupt, corresponding flag is here
RFC_DBELL:RFHWIFG
1Bh = Combined Interrupt for CPE Generated events.
Corresponding flags are here RFC_DBELL:RFCPEIFG. Only
interrupts selected with CPE0 in RFC_DBELL:RFCPEIFG can trigger
a RFC_CPE_0 event
1Eh = Combined Interrupt for CPE Generated events.
Corresponding flags are here RFC_DBELL:RFCPEIFG. Only
interrupts selected with CPE1 in RFC_DBELL:RFCPEIFG can trigger
a RFC_CPE_1 event
22h = SSI0 combined interrupt, interrupt flags are found here
SSI0:MIS
23h = SSI0 combined interrupt, interrupt flags are found here
SSI1:MIS
24h = UART0 combined interrupt, interrupt flags are found here
UART0:MIS
3Dh = GPT0A compare event. Configured by GPT0:TAMR.TCACT
3Eh = GPT0B compare event. Configured by GPT0:TBMR.TCACT
3Fh = GPT1A compare event. Configured by GPT1:TAMR.TCACT
40h = GPT1B compare event. Configured by GPT1:TBMR.TCACT
41h = GPT2A compare event. Configured by GPT2:TAMR.TCACT
42h = GPT2B compare event. Configured by GPT2:TBMR.TCACT
43h = GPT3A compare event. Configured by GPT3:TAMR.TCACT
44h = GPT3B compare event. Configured by GPT3:TBMR.TCACT
5Bh = Port capture event from IOC, configured by
IOC:IOCFGn.PORT_ID. Events on ports configured with ENUM
PORT_EVENT6 will be routed here.
5Ch = Port capture event from IOC, configured by
IOC:IOCFGn.PORT_ID. Events on ports configured with ENUM
PORT_EVENT7 will be routed here.
61h = RFC RAT event 6, configured by RFC_RAT:RATEV.OEVT6
62h = RFC RAT event 7, configured by RFC_RAT:RATEV.OEVT7
69h = AON wake-up event, corresponds flags are here
AUX_EVCTL:EVTOMCUFLAGS.AON_WU_EV
6Ah = AUX Compare A event, corresponds to
AUX_EVCTL:EVTOMCUFLAGS.AUX_COMPA
6Bh = AUX Compare B event, corresponds to
AUX_EVCTL:EVTOMCUFLAGS.AUX_COMPB
6Ch = AUX TDC measurement done event, corresponds to the flag
AUX_EVCTL:EVTOMCUFLAGS.TDC_DONE and the AUX_TDC
status AUX_TDC:STAT.DONE
6Dh = AUX timer 0 event, corresponds to
AUX_EVCTL:EVTOMCUFLAGS.TIMER0_EV
6Eh = AUX timer 1 event, corresponds to
AUX_EVCTL:EVTOMCUFLAGS.TIMER1_EV
6Fh = Auto-take event from AUX semaphore, configured by
AUX_SMPH:AUTOTAKE
70h = AUX ADC done, corresponds to
Copyright © 2015, Texas Instruments Incorporated
SWCU117C – February 2015 – Revised September 2015
Submit Documentation Feedback
www.ti.com